Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-254 kPa (22-37 psi) | 1033-1412 kPa (150-205 psi) | 9°C (48°F) |
19-24°C (66-75°F) | Below 40% | 151-234 kPa (22-34 psi) | 1150-1550 kPa (167-225 psi) | 8°C (46°F) |
Above 40% | 165-275 kPa (24-40 psi) | 1233-1557 kPa (179-226 psi) | 12°C (52°F) | |
25-29°C (76-85°F) | Below 35% | 165-254 kPa (24-37 psi) | 1240-1619 kPa (180-235 psi) | 10°C (50°F) |
35-50% | 186-261 kPa (27-38 psi) | 1391-1722 kPa (202-250 psi) | 12°C (52°F) | |
Above 50% | 206-289 kPa (30-42 psi) | 1419-1736 kPa (206-252 psi) | 13°C (55°F) | |
30-35°C (86-95°F) | Below 30% | 199-282 kPa (29-41 psi) | 1508-1791 kPa (219-260 psi) | 13°C (55°F) |
30-50% | 206-289 kPa (30-42 psi) | 1502-1812 kPa (218-263 psi) | 14°C (57°F) | |
Above 50% | 227-303 kPa (33-44 psi) | 1515-1839 kPa (220-267 psi) | 15°C (59°F) | |
36-41°C (96-105°F) | Below 20% | 234-316 kPa (34-46 psi) | 1688-1970 kPa (245-286 psi) | 17°C (61°F) |
20-40% | 241-316 kPa (35-46 psi) | 1701-1977 kPa (247-287 psi) | 18°C (63°F) | |
Above 40% | 248-316 kPa (36-46 psi) | 1722-1977 kPa (250-287 psi) | 18°C (63°F) | |
42-46°C (106-115°F) | Below 20% | 275-351 kPa (40-51 psi) | 1887-2129 kPa (274-309 psi) | 19°C (66°F) |
Above 20% | 275-337 kPa (40-49 psi) | 1887-2122 kPa (274-308 psi) | 19°C (66°F) | |
47-49°C (116-120°F) | Below 30% | 310-392 kPa (45-57 psi) | 2053-2335 kPa (298-339 psi) | 22°C (70°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 117-192 kPa (17-28 psi) | 971-1322 kPa (141-192 psi) | 8°C (46°F) |
19-24°C (66-75°F) | Below 40% | 158-227 kPa (23-33 psi) | 1019-1322 kPa (148-192 psi) | 9°C (48°F) |
Above 40% | 137-261 kPa (20-38 psi) | 999-1412 kPa (145-205 psi) | 13°C (54°F) | |
25-29°C (76-85°F) | Below 35% | 186-254 kPa (27-37 psi) | 1178-1433 kPa (171-208 psi) | 13°C (54°F) |
35-50% | 179-261 kPa (26-38 psi) | 1240-1557 kPa (180-226 psi) | 13°C (55°F) | |
Above 50% | 186-275 kPa (27-40 psi) | 1260-1529 kPa (183-222 psi) | 15°C (59°F) | |
30-35°C (86-95°F) | Below 30% | 192-282 kPa (28-41 psi) | 1302-1653 kPa (189-240 psi) | 14°C (57°F) |
30-50% | 213-303 kPa (31-44 psi) | 1336-1715 kPa (194-249 psi) | 17°C (61°F) | |
Above 50% | 220-323 kPa (32-47 psi) | 1378-1763 kPa (200-256 psi) | 19°C (66°F) | |
36-41°C (96-105°F) | Below 20% | 227-303 kPa (33-44 psi) | 1412-1688 kPa (205-245 psi) | 18°C (63°F) |
20-40% | 234-323 kPa (34-47 psi) | 1460-1729 kPa (212-251 psi) | 19°C (66°F) | |
Above 40% | 254-351 kPa (37-51 psi) | 1488-1770 kPa (216-257 psi) | 22°C (70°F) | |
42-46°C (106-115°F) | Below 20% | 254-323 kPa (37-47 psi) | 1570-1812 kPa (228-263 psi) | 19°C (66°F) |
Above 20% | 261-358 kPa (38-52 psi) | 1612-1853 kPa (234-269 psi) | 22°C (70°F) | |
47-49°C (116-120°F) | Below 30% | 275-365 kPa (40-53 psi) | 1729-1998 kPa (251-290 psi) | 23°C (73°F) |