Warning: Do not allow smoking or the use of open flames in the area where work on the fuel or EVAP system is taking place. Anytime work is being done on the fuel system, disconnect the negative battery cable, except for those tests where battery voltage is required.
Note: Replacement fuel filler tube hoses do not come equipped with hose clamps. Obtain replacement hose clamps prior to beginning this service procedure.
Caution: Refer to Fastener Caution in the Preface section.
Tighten
Tighten the bolt to 9 N·m (80 lb in).
Note: Ensure that the fuel fill tube connecting hose is installed until it touches the fuel tank body. The hose clamp should be located within 13 mm (1/2 in) of the end of the connecting hose.
Tighten
Tighten the clamp to 5 N·m (44 lb in).