Removal Procedure
- Remove the air cleaner inlet duct. Refer to
Air Cleaner Inlet Duct Replacement.
- Disconnect the engine wiring harness electrical connector from the camshaft position (CMP) sensor.
- Remove the CMP sensor bolt (2).
- Remove the CMP sensor (1).
- Inspect the CMP sensor O-rings for wear, cracks, or leakage if the sensor is being reused. Replace the O-rings if damaged.
Installation Procedure
- Lubricate the CMP sensor O-rings with clean engine oil.
- Install the CMP sensor (1).
Caution: Refer to Fastener Caution in the Preface section.
- Install the CMP sensor bolt (2).
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Connect the engine wiring harness electrical connector to the CMP sensor.
- Install the air cleaner inlet duct. Refer to
Air Cleaner Inlet Duct Replacement.