• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ | 1 | 1 | -- | -- |
Park Neutral Signal | 2 | 1 | 1 | -- |
CRNK Relay Control | 1 | 1 | 3 | -- |
Starter Control | 1 | 1 | 3 | -- |
Ground | -- | 1 | -- | -- |
|
When the ignition switch is placed in the START position, a discrete signal is supplied to the body control module (BCM) notifying it that the ignition is in the START position. The BCM then sends a message to the engine control module (ECM) that crank has been requested. The ECM then verifies that the transmission is in Park or Neutral. If it is, the ECM then supplies 12 volts to the control circuit of the crank relay. When this occurs, battery voltage is supplied through the switch of the crank relay to terminal A X1 of the starter solenoid.
Starting and Charging Schematics
Starting System Description and Operation
Control Module References for scan tool information
⇒ | If not the specified value, refer to PNP Switch Circuit Malfunction. |
⇒ | If the solenoid does not engage, refer to CRNK Relay Circuit Malfunction. |
⇒ | If the solenoid engages but the engine does not crank, refer to Starter Solenoid Clicks, Engine Does Not Crank. |
⇒ | If not the specified value, test the signal circuit terminal 5 for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the STRTR fuse is open, test the starter control circuit terminal 87 for a short to ground. |
⇒ | If the engine does not crank, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the starter. |
⇒ | If the test lamp is always ON, test the relay control circuit terminal 86 for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the relay control circuit terminal 86 for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup and programming. |