Removal Procedure
- Remove the instrument panel upper trim panel. Refer to
Instrument Panel Upper Trim Panel Replacement.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the recirculation actuator screws from the HVAC module.
- Remove the recirculation actuator from the HVAC module.
Installation Procedure
- Align the recirculation actuator with the door shaft and rotate into position.
Caution: Refer to Fastener Caution in the Preface section.
- Install the recirculation actuator screws to the HVAC module.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the recirculation actuator.
- Calibrate the actuators. Refer to
Actuator Recalibration.
- Cycle the ignition and verify proper operation.
- Install the instrument panel upper trim panel. Refer to
Instrument Panel Upper Trim Panel Replacement.