Special Tools
• | J-45166 Dial Indicator Extension Rod - 8 Inch |
• | J-45200 Dial Indicator Set
|
- Install
J-45166 extension
into the fluid pump assembly bolt hole (1) indicated with the arrow.
- Assemble
J-45200 indicator
(1) onto
J-45166 extension
(2) and set the dial indicator to zero on the second clutch piston.
Warning: Wear safety glasses when using compressed air in order to prevent eye injury.
- Apply compressed air into the second clutch fluid passage (B2) and measure the piston stroke. Be sure the piston moves smoothly.
- If the piston stroke is out of specifications, select another second clutch backing plate. Second clutch piston bore stroke:
1.10 - 1.50 mm (0.043 - 0.059 in).