Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the HVAC Blower Controls System Check performed? | -- | Go to Step 2 | |||||||||||
2 |
Does the test lamp light? | -- | Go to Step 13 | Go to Step 3 | ||||||||||
3 | Connect an unpowered test lamp between the auxiliary blower motor resistor, cavity A for CKT 1176 (YEL), and ground. Does the test lamp light? | -- | Go to Step 14 | Go to Step 4 | ||||||||||
4 | Connect an unpowered test lamp between the auxiliary blower motor resistor connector, cavity C for CKT 1072 (LT BLU), and ground. Does the test lamp light? | -- | Go to Step 15 | Go to Step 5 | ||||||||||
5 |
Does the auxiliary blower motor operate? | -- | Go to Step 6 | Go to Step 8 | ||||||||||
6 | Disconnect the front auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 16 | Go to Step 7 | ||||||||||
7 |
Is continuity present? | -- | Go to Step 17 | Go to Step 18 | ||||||||||
8 | Connect the auxiliary blower motor medium speed relay connector. Does the auxiliary blower motor operate? | -- | Go to Step 9 | Go to Step 11 | ||||||||||
9 | Disconnect the front auxiliary HVAC control module connector. Does the auxiliary blower motor cease operating? | -- | Go to Step 16 | Go to Step 10 | ||||||||||
10 |
Is continuity present? | -- | Go to Step 19 | Go to Step 20 | ||||||||||
11 | Disconnect the front auxiliary HVAC control module. Connect a J 39200 between the front auxiliary HVAC module connector, cavity D, and cavity F. Is continuity present? | -- | Go to Step 21 | Go to Step 12 | ||||||||||
12 | Connect a J 39200 between the front auxiliary HVAC control module, pin D, and pin F. Is continuity present? | -- | Go to Step 16 | Go to Step 22 | ||||||||||
13 | Repair the short to voltage in CKT 1172 (YEL) between the auxiliary blower motor connector, auxiliary blower motor resistor connector, and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
14 | Repair the short to voltage in CKT 1176 (YEL) between the auxiliary blower motor resistor connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
15 | Repair the short to voltage in CKT 1072 (LT BLU) between the auxiliary blower motor resistor connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
16 | Replace the front auxiliary HVAC control module. Refer to Control Switch Replacement - Auxiliary . Is the repair complete? | -- | -- | |||||||||||
17 | Repair the short to ground in CKT 1926 (DK BLU)/CKT 60 (YEL) between the front auxiliary HVAC control module connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
18 | Replace the auxiliary blower motor low speed relay. Isthe repair complete? | -- | -- | |||||||||||
19 | Repair the short to ground in CKT 1925 (RED) / 63 (TAN) between the front auxiliary HVAC control module connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
20 | Replace the auxiliary blower motor medium speed relay. Is the repair complete? | -- | -- | |||||||||||
21 | Repair the short to ground in CKT 1924 (WHT) / CKT 52 (ORN) between the front auxiliary HVAC control module connector and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
22 | Replace the auxiliary blower motor high speed relay. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the HVAC Blower Controls System Check performed? | -- | Go to Step 2 | |||||||||||
2 |
Does the test lamp light? | -- | Go to Step 15 | Go to Step 3 | ||||||||||
3 | Connect an unpowered test lamp between the auxiliary blower motor resistor, cavity A for CKT 1176 (YEL), and ground. Does the test lamp light? | -- | Go to Step 16 | Go to Step 4 | ||||||||||
4 | Connect an unpowered test lamp between the auxiliary blower motor resistor connector, cavity C for CKT 1072 (LT BLU), and ground. Does the test lamp light? | -- | Go to Step 17 | Go to Step 5 | ||||||||||
5 |
Does the auxiliary blower motor operate? | -- | Go to Step 6 | Go to Step 9 | ||||||||||
6 | Disconnect the front auxiliary HVAC control module connector. Does the auxiliary blower motor cease operating? | -- | Go to Step 18 | Go to Step 7 | ||||||||||
7 | Disconnect the rear auxiliary HVAC control module connector. Does the auxiliary blower motor cease operating? | -- | Go to Step 19 | Go to Step 8 | ||||||||||
8 |
Is continuity present? | -- | Go to Step 20 | Go to Step 21 | ||||||||||
9 | Connect the auxiliary blower motor medium speed relay connector. Does the auxiliary blower motor operate? | -- | Go to Step 10 | Go to Step 13 | ||||||||||
10 | Disconnect the front auxiliary HVAC control module connector. Does the auxiliary blower motor cease operating? | -- | Go to Step 18 | Go to Step 11 | ||||||||||
11 | Disconnect the rear auxiliary HVAC control module connector. Does the auxiliary blower motor cease operating? | -- | Go to Step 19 | Go to Step 12 | ||||||||||
12 |
Is continuity present? | -- | Go to Step 22 | Go to Step 23 | ||||||||||
13 |
Is continuity present? | -- | Go to Step 14 | Go to Step 18 | ||||||||||
14 |
Is continuity present? | -- | Go to Step 24 | Go to Step 25 | ||||||||||
15 | Repair the short to voltage in CKT 1172 (YEL) between the auxiliary blower motor connector, auxiliary blower motor resistor connector, and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
16 | Repair the short to voltage in CKT 1176 (YEL) between the auxiliary blower motor resistor connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
17 | Repair the short to voltage in CKT 1072 (LT BLU) between the auxiliary blower motor resistor connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
18 | Replace the front auxiliary HVAC control module. Refer to Control Switch Replacement - Auxiliary . Is the repair complete? | -- | -- | |||||||||||
19 | Replace the rear auxiliary HVAC control module. Refer to Control Switch Replacement - Auxiliary . Is the repair complete? | -- | -- | |||||||||||
20 | Repair the short to ground in CKT 1926 (DK BLU) / 60 (YEL) between the following components:
Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
21 | Replace the auxiliary blower motor low speed relay. Is the repair complete? | -- | -- | |||||||||||
22 | Repair the short to ground in CKT 1925 (RED) / 63 (TAN) between the following components:
Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
23 | Replace the auxiliary blower motor medium speed relay. Is the repair complete? | -- | -- | |||||||||||
24 | Repair the short to ground in CKT 1924 (WHT) / 52 (ORN) between the following components:
Refer to Wiring Repairs . Is the repair complete? | -- | -- | |||||||||||
25 | Replace the auxiliary blower motor high speed relay. Is the repair complete? | -- | -- |