Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Exterior Lights System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 1040 (ORN) between the instrument panel fuse block and connector C200. Are the hazard lamps operative? | -- | Go to Step 4 | |
4 |
Is continuity present? | -- | Go to Step 7 | Go to Step 5 |
5 |
Are the hazard lamps operative? | -- | Go to Step 6 | |
6 | Replace the hazard warning switch. Are the hazard lamps operative? | -- | Go to Step 8 | |
7 | Connect a J 39200 DMM between connector C200, cavity E9 for the pigtail wire of CKT 16 (PPL), and cavity A6 for the pigtail wire of CKT 15 (DK BLU). Is continuity present? | -- | Go to Step 8 | Go to Step 6 |
8 |
Is continuity present? | -- | Go to Step 10 | Go to Step 9 |
9 | Repair the open in CKT 62 (LT GRN) between the connector C200 and the turn/hazard lamp flasher. Are the hazard lamps operative? | -- | Go to Step 10 | |
10 | Connect a J 39200 DMM between the turn/hazard lamp flasher connector, cavity C8 for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the turn/hazard lamp flasher. Are the hazard lamps operative? | -- | Go to Step 12 | |
12 | Repair the open in CKT 150 (BLK) between the turn/hazard lamp flasher and ground G201. Are the hazard lamps operative? | -- | -- |