Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Exterior Lights System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the open in CKT 17 (WHT) between connector C202 and splice S410. Are all of the stoplamps operative? | -- | Go to Step 4 | |
4 |
Is contiuity present? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 17 (WHT) between the TCC/stoplamp switch and splice S114. Are all of the stoplamps operative? | -- | Go to Step 6 | |
6 | Connect an unpowered test lamp between the TCC/stoplamp switch connector, cavity E for CKT 140 (ORN), and ground. Does the test lamp light? | -- | Go to Step 7 | Go to Step 9 |
7 | Adjust the TCC/stoplamp switch. Are all of the stoplamps operative? | -- | Go to Step 8 | |
8 | Replace the TCC/stoplamp switch. Are all of the stoplamps operative? | -- | Go to Step 9 | |
9 | Repair the open in CKT 140 (ORN) between the instrument panel fuse block and the TCC/stoplamp switch. Are all of the stoplamps operative? | -- | -- |