Tools Required
J 29714-A
Servo Cover Depressor
Removal Procedure
- Raise the vehicle. Refer to
Lifting and Jacking the Vehicle
in General information.
- Remove the oil pan bolt below and to the left of the 2-4 servo cover.
- Install the
J 29714-A
to the oil pan rail.
- Tighten the bolt on the
J 29714-A
in
order to compress the servo cover.
- Remove the servo cover retaining ring.
- Loosen the bolt on the
J 29714-A
to release tension on the servo cover.
- Remove the servo cover and O-ring seal. If the cover is hung up on the seal, use a pick (2) to pull and stretch the seal (1) out
of the groove. Cut and remove the O-ring seal before removing the cover.
- Remove the 2-4 servo assembly from the transmission.
- Inspect the 4th apply piston, the 2-4 servo converter, 2nd apply piston, and the piston inner housing for the following defects:
Installation Procedure
- Install the new seals on the pistons and the servo cover.
- Lubricate the seals with clean transmission fluid.
- Install the 2-4 servo assembly into the 2-4 servo bore.
- Install the servo cover and O-ring seal.
- Install the
J 29714-A
.
- Tighten the bolt on the
J 29714-A
in
order to compress the servo cover.
- Install the servo cover retaining ring.
- Remove the
J 29714-A
from the oil pan flange.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the oil pan bolt.
Tighten
Tighten the oil pan bolt to 11 N·m (97 lb in).
- Lower the vehicle.
- Fill the transmission to the proper level with approved fluid.
Important: It is recommended that the transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, the ECM, PCM or TCM
will need to relearn the TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function
.