Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Seat Belt Schematics | |||
1 | Did you review the Diagnostic Starting Point - Seat Belts? | Go to Step 2 | |
2 |
Does the seat belt indicator illuminate during bulb check? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the seat belt indicator illuminate? | Go to Step 7 | Go to Step 4 |
4 |
Did you find and correct the condition? | Go to Step 10 | Go to Step 5 |
5 | Test the instrument cluster ground circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 6 |
6 |
Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
7 | Inspect the multifunction alarm module connector for corrosion or damage. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
8 | Repair or replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages and Console. Did you complete the replacement? | Go to Step 10 | -- |
9 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gages and Console. Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |