Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Seat Belt Schematics | |||
1 | Did you review the Diagnostic Starting Point - Seat Belts? | Go to Step 2 | |
2 |
Does the seat belt indicator remain OFF? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the seat belt indicator turn OFF? | Go to Step 6 | Go to Step 4 |
4 | Test the seat belt indicator control circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 5 |
5 |
Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Inspect the multifunction alarm module connector for corrosion or damage. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Repair or replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages and Console. Did you complete the replacement? | Go to Step 9 | -- |
8 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gages and Console. Did you complete the replacement? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |