Note: Note wire routing prior to removal.
Caution: Refer to Fastener Caution in the Preface section.
Note:
• Ensure outside surface of sensor body is clean and oil-free prior to beginning the installation procedure. If sensor body surface is oily, use a mild degreaser in order to remove the oil from the surface. Ensure degreased surface is dry prior to
beginning the installation. • The thermal reflective shield and tie strap are to be installed over the vane position sensor AFTER the sensor is installed and torqued in the turbo centerhousing. Graphics below show the sensor prior to the installation process for clarity purposes
only.