• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ | P0622 | P0622 | -- | -- |
Generator Field Duty Cycle Signal | P0622 | P0622 | P0622 | P0622 |
The engine control module (ECM) uses the generator field duty cycle signal circuit to monitor the duty cycle of the generator. The generator field duty cycle signal circuit connects to high side of the field windings in the generator. A pulse width modulated (PWM) high side driver in the voltage regulator turns the field windings ON and OFF. The ECM uses the PWM signal input to determine the generator load on the engine. This allows the ECM to adjust the idle speed to compensate for high electrical loads. The ECM monitors the status of the generator field duty cycle signal circuit. When the Ignition is in the RUN position and the engine is OFF, the ECM should detect a duty cycle near 0 percent. However, when the engine is running, the duty cycle should be between 5-95 percent.
• | No generator, crankshaft position (CKP) sensor, or camshaft (CMP) sensor DTCs are set. |
• | Ignition ON engine OFF, for the Ignition ON test. |
• | Engine running, engine speed less than 3,000 RPM for the RUN test. |
• | Ignition ON engine OFF, the ECM detects a PWM signal that is greater than 65 percent for 5 seconds. |
• | Engine running, the ECM detects a PWM signal that is less than 5 percent for 15 seconds. |
DTC P0622 is a C type DTC.
DTC P0622 is a C type DTC.
Starting and Charging Schematics
Charging System Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
With the scan tool installed, ignition ON and the Engine running, observe the scan tool ECM GEN-F Terminal Signal parameter. The parameter should read between 5 and 95 percent.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If greater than the specified range, test the signal circuit terminal C X1 for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.