GM Service Manual Online
For 1990-2009 cars only

Circuit Description

An ignition voltage is supplied to the Low Pressure Lock-Off (LPL) solenoid through the LPL Relay. The PCM controls the LPL Relay by grounding the control circuit via an internal switch called a driver. The primary function of the driver is to supply the ground for the controlled component. The PCM monitors the status of the driver. If the PCM detects an incorrect voltage for the commanded state of the driver, DTC P2665 sets.

Conditions for Running the DTC

The ignition is ON.

Conditions for Setting the DTC

    • The control module detects that the commanded state of the driver and the actual state of the control circuit do not match.
    • The above condition exists for at least 1 seconds.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. This step tests if the concern is active. You should hear a clicking sound when the LPL Relay is commanded ON and OFF. Repeat the commands as necessary.

  2. This step verifies that the control module is providing ground to the LPL Relay.

  3. This step tests if a ground is constantly being applied to the LPL Relay.

Step

Action

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check Alternative Fuels - Engine Controls?

Go to Step 2

Go to Diagnostic System Check - Alternative Fuels (Engine Controls)

2

  1. Turn ON the ignition, with the engine OFF.
  2. Command the LPL Relay ON and OFF with a scan tool.

Does the LPL Relay respond to the scan tool commands?

Go to Step 3

Go to Step 4

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30  seconds.
  3. Turn ON the ignition, with the engine OFF.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 4

Go to Intermittent Conditions

4

  1. Turn OFF the ignition.
  2. Disconnect the LPL Relay.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the ignition voltage circuit of the LPL Relay with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 5

Go to Step 11

5

  1. Connect a test lamp between the control circuit of the LPL Relay and the ignition voltage circuit of the LPL Relay.
  2. Command the LPL Relay ON and OFF with a scan tool.

Does the test lamp turn ON and OFF with each command?

Go to Step 9

Go to Step 6

6

Does the test lamp remain illuminated with each command?

Go to Step 8

Go to Step 7

7

Test the control circuit of the LPL Relay for an open or for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems in the G/H Van Service Manual.

Did you find and correct the condition?

Go to Step 14

Go to Step 10

8

Test the control circuit of the LPL Relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems in the G/H Van Service Manual.

Did you find and correct the condition?

Go to Step 14

Go to Step 13

9

Inspect for poor connections at the LPL Relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems in the G/H Van Service Manual.

Did you find and correct the condition?

Go to Step 14

Go to Step 12

10

Inspect for poor connections at the harness connector of the control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems in the G/H Van Service Manual.

Did you find and correct the condition?

Go to Step 14

Go to Step 13

11

Repair the open or short to ground in the ignition voltage circuit. Refer to Wiring Repairs in Wiring Systems in the G/H Van Service Manual.

Did you complete the repair?

Go to Step 14

--

12

Replace the LPL Relay.

Did you complete the replacement?

Go to Step 14

--

13

Replace the PCM. Refer to Powertrain Control Module Replacement in Engine Controls in the G/H Van Service Manual.

Did you complete the replacement?

Go to Step 14

--

14

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30  seconds.
  3. Turn ON the ignition, with the engine OFF.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 2

Go to Step 15

15

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

Go to Diagnostic Trouble Code (DTC) List

System OK