The Keyless Entry/Access Panel Scan Tool Data List contains all of the related parameters that are available on the scan tool. The parameters in the list are arranged in alphabetical order. The column, Data List, indicates the location of the parameter within the scan tool menu selections. Use the Keyless Entry/Access Panel Scan Tool Data List as directed by a diagnostic table or in order to supplement the diagnostic procedures. Begin all of the diagnostic procedures with Diagnostic System Check - Vehicle .
Use the Scan Tool Data List only after the following are determined:
• | There is no published DTC procedure nor published symptom procedure for the customer concern. |
• | The DTC or symptom diagnostic procedure indicated by the diagnostic system check does not resolve the customer concern. |
The Typical Data Values are obtained from a properly operating vehicle under the conditions specified in the first row of the Scan Tool Data List table. Comparison of the parameter values from the suspect vehicle with the Typical Data Values may reveal the source of the customer concern.
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Ignition in RUN, Engine OFF | |||
8-Digit GM Part Number | RFA/Data Display/Module Information | 8 digit number | 12345678 |
No. of Fobs Programmed | RFA/Data Display/Key FOB Information | 1 Fob, 2 Fobs, 3 Fobs, 4 Fobs | 2 Fobs |
Calibration ID | RFA/Data Display/Module Information | 4 digit number | 0001 |
Invalid Transmitter | RFA/Data Display/Key FOB Information | Greater than or less than 10 counts | Less than 10 counts |
Key Fob 1 Low Voltage | RFA/Data Display/Key FOB Information | Counts | 0 |
Key Fob 1 Battery Status | RFA/Data Display/Key FOB Information | OK/Low | OK |
Key Fob 2 Low Voltage | RFA/Data Display/Key FOB Information | Counts | 0 |
Key Fob 2 Battery Status | RFA/Data Display/Key FOB Information | OK/Low | OK |
Key Fob 3 Low Voltage | RFA/Data Display/Key FOB Information | Counts | 0 |
Key Fob 3 Battery Status | RFA/Data Display/Key FOB Information | OK/Low | OK |
Key Fob 4 Low Voltage | RFA/Data Display/Key FOB Information | Counts | 0 |
Key Fob 4 Battery Status | RFA/Data Display/Key FOB Information | OK/Low | OK |
Key Pressed On Fob | RFA/Data Display/Key FOB Information | Dr Door Unlock, All Door Unlock, Door Lock | Unlock |
Last Fob Used | RFA/Data Display/Key FOB Information | Fob # | Fob 2 |
Left Side Front Access Panel | BCM/Data Display/Outputs | On/Off | Off |
Left Side Rear Access Panel | BCM/Data Display/Outputs | On/Off | Off |
PROM ID | RFA/Data Display/Module Information | 4 digit number | 9060 |
Right Side Rear Access Panel | BCM/Data Display/Outputs | On/Off | Off |