Removal Procedure
- Remove the evaporator core. Refer to
Auxiliary Air Conditioning Evaporator Replacement
.
- Gently remove the sealer packed around the thermal expansion valve (TXV).
Important: Note the mounting location and the orientation of the tube on the core.
- Remove the clip retaining the capillary tube to the evaporator core.
- Disconnect the evaporator tube connections from the TXV.
- Remove the TXV from the core.
Installation Procedure
- Install the TXV to the core.
Notice: Refer to Fastener Notice in the Preface section.
- Connect the evaporator tube connections to the TXV.
Tighten
Tighten the tube connections to 28 N·m (21 lb ft).
Important: Install the clip and the tube in the location and the orientation as noted during the disassembly.
- Install the clip in order to retain the capillary tube to the evaporator core.
- Pack sealer around the TXV in the manner found during the disassembly.
- Install the evaporator core. Refer to
Auxiliary Air Conditioning Evaporator Replacement
.