The numbers below refer to the step numbers on the diagnostic table.
Test the circuit that did not illuminate the test lamp in Step 6.
The control circuit of the auxiliary blower motor relay is the circuit which provides the ground path for the relay coil through the auxiliary blower motor switch esi.
Test the blower motor control circuit that corresponds with the inoperative blower motor speed.
The auxiliary blower motor switch control circuit is the circuit that enables the rear auxiliary HVAC control assembly when the front auxiliary blower motor switch is placed in the rear control position.
The auxiliary blower motor switch control circuit is the circuit that enables the rear auxiliary HVAC control assembly when the front auxiliary blower motor switch is placed in the rear control position.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor operates in at least one, but not all, speed positions. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Does the auxiliary blower motor operate properly in each speed position? | Go to Step 3 | Go to Step 5 |
3 | Is the vehicle equipped with both front and rear auxiliary HVAC control assemblies? | Go to Step 4 | Go to Testing for Intermittent Conditions and Poor Connections |
4 |
Does the auxiliary blower motor operate properly in each speed position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 13 |
5 |
Does the test lamp illuminate in each speed position? | Go to Step 12 | Go to Step 6 |
6 |
Does the test lamp illuminate on each circuit? | Go to Step 20 | Go to Step 7 |
Test the applicable circuit between the auxiliary blower motor resistor assembly and the corresponding auxiliary blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 8 | |
8 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 25 |
9 | Connect a test lamp between the battery positive voltage circuit of the auxiliary blower motor relay and a good ground. Does the test lamp illuminate? | Go to Step 10 | Go to Step 26 |
Does the test lamp illuminate? | Go to Step 19 | Go to Step 11 | |
11 | Test the applicable control circuit of the auxiliary blower motor relay between the relay and the front auxiliary HVAC control assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 22 |
12 | Test the ground circuit of the auxiliary blower motor for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 21 |
13 | Does the auxiliary blower motor operate in any rear auxiliary blower motor switch speed position? | Go to Step 14 | Go to Step 15 |
Test the applicable blower motor control circuit of the rear auxiliary HVAC control assembly between the rear auxiliary HVAC control assembly and the splice for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 23 | |
Does the auxiliary blower motor operate? | Go to Step 22 | Go to Step 16 | |
Does the auxiliary blower motor operate? | Go to Step 17 | Go to Step 18 | |
17 | Test the auxiliary blower motor switch control circuit between the front auxiliary HVAC control assembly and the auxiliary HVAC control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 24 |
18 | Test the auxiliary blower motor switch control circuit between the rear auxiliary HVAC control assembly and the auxiliary HVAC control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 23 |
19 | Inspect for poor connections at the harness connector of the applicable auxiliary blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 27 |
20 | Inspect for poor connections at the harness connector of the auxiliary blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 28 |
21 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 29 |
22 | Inspect for poor connections at the harness connector of the auxiliary blower motor switch, without rear A/C, or the front auxiliary HVAC control assembly, with rear A/C. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 30 |
23 | Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 31 |
24 | Inspect for poor connections at the harness connector of the auxiliary HVAC control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 33 | Go to Step 32 |
25 | Repair the ignition 3 voltage circuit between the splice and the relay for an open or high resistance. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 33 | -- |
26 | Repair the battery positive voltage circuit between the splice and the relay for an open or high resistance. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 33 | -- |
27 | Replace the appropriate auxiliary blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement . Did you complete the replacement? | Go to Step 33 | -- |
28 | Replace the auxiliary blower motor resistor assembly. Refer to Auxiliary Blower Motor Resistor Assembly Replacement . Did you complete the replacement? | Go to Step 33 | -- |
29 | Replace the auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement . Did you complete the replacement? | Go to Step 33 | -- |
30 | Replace the auxiliary blower motor switch, without rear A/C, or the front auxiliary HVAC control assembly, with rear A/C. Refer to Auxiliary Blower Motor Switch Replacement or Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | Go to Step 33 | -- |
31 | Replace the rear auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Rear . Did you complete the replacement? | Go to Step 33 | -- |
32 | Replace the auxiliary HVAC control processor. Refer to Auxiliary HVAC Control Processor Replacement . Did you complete the replacement? | Go to Step 33 | -- |
33 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |