• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Crankshaft 58 X - 5-Volt Reference | P0642 | P0335, P2453 | P0335, P2453 | P0341, P0401, P0643 | -- |
Camshaft 4 X - 5-Volt Reference | P0642 | P0340 | P0340 | P0340, P0401, P0643 | -- |
Intake Air Flow Valve | P0642 | P02E7 | P02E8 | P0401, P0643 | -- |
Fuel Tank Level Sensor 2 | P0642, P2067 | P2068 | P2068 | P0643, P2068 | -- |
The engine control module (ECM) supplies 5 volts to components through 5-volt reference circuits. These 5-volt reference circuits are independent of each other outside the ECM, but are bussed together in three reference groups inside the ECM. Therefore, a circuit condition on one sensor 5-volt reference circuit may affect multiple components. The ECM monitors voltage on the 5-volt reference circuits.
• | The ignition is ON. |
• | The diagnostics run continuously. |
• | The ECM detects the 5-volt reference 1 circuit voltage is less than 4.7 volts. |
• | The above condition is present for 2 seconds. |
• | The ECM detects the 5-volt reference 1 circuit voltage is more than 5.2 volts. |
• | The above condition is present for 2 seconds. |
DTC P0642 and P0643 are Type A DTCs.
DTC P0642 and P0643 are Type A DTCs.
Important: Additional DTCs will set when disconnecting the components.
Important: A short to voltage on the signal circuit of certain components may cause this DTC to set.
⇒ | If the voltage is less than the specified range, test for a short to ground on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. |
⇒ | If the voltage is greater than the specified range, test for a short to voltage on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. |
⇒ | If the voltage display increases greater than the specified value when a component is connected, test the signal circuit for a short to voltage. If all circuits test normal, replace the ECM. |
⇒ | If the voltage display decreases more than the specified value when a component is connected, replace the component. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |