- Inspect the wiring harness and solenoid assembly for the following conditions:
• | Loose electrical terminals |
• | Damaged wiring loom and conduit |
• | Worn, missing, or cut pass-through connector O-ring seal. |
- Install the transmission wiring harness pass-through connector into the transmission case. Ensure connector tabs lock into place.
- Move the harness to one side in order to install the valve body.
Note: Valve bodies are model dependent.
- Install the ball check valves (2-6, 8, 12) in the valve body and retain ball check valves with
J 36850 transjel lubricant
or an equivalent.
Caution: Be sure all solenoids are installed with the electrical connectors facing the non-machined (cast) side of the valve body; otherwise, the solenoids will bind against the transmission
case as the valve body bolts are tightened and damage may occur.
- Install the valve body over the
J 25025-5 mounting post
, and connect the manual valve link to the manual valve.
- Install 2 valve body bolts to hold the valve body in place.
- Remove the
J 25025-5 mounting post
.
- Install the 12 valve body bolts (62), 2 bolts (59) and 3 bolts (120) that are shown only.
- Finger tighten the bolts.
- Install the transmission wiring harness on the valve body.
Caution: Refer to Fastener Caution in the Preface section.
- Install the torque converter clutch (TCC) solenoid valve and bolts (68). Tighten the bolts to
8-14 N·m (6-10 lb ft).
Caution: Do not over-tighten the bolts. Over-tightening the bolts will distort the valve bores. Begin tightening from the center of the valve body tighten the bolts in a outward direction.
- Inspect to ensure all of the valve body bolts are in the correct location.
Each bolt number refers to a specific bolt size, as indicated in the following list:
• | 59 - M6 x 1.0 x 35.0 (Qty: 2) |
• | 62 - M6 x 1.0 x 47.5 (Qty: 12) |
• | 120 - M6 x 1.0 x 54.4 (Qty: 3) |
- Tighten the bolts from the center of the valve body working your way out in a spiral pattern to the outside edge. Tighten the bolts to
8-14 N·m (6-10 lb ft).
- Install the torque converter clutch pulse width modulation (TCC PWM) solenoid valve (396)
and the solenoid retainer (395).
- Snap the wiring harness in place on the valve body bolts. Ensure the harness loom tab is located under the TFP switch.
- Install the wiring connectors to the electrical components as indicated in the following list:
• | 1 - Manual shift detent lever with shaft position switch assembly |
• | 4 - Pressure control solenoid (PCS) |
• | 6 - Input speed sensor (ISS) |