Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
- Disconnect the intake (3) or exhaust (2) camshaft position actuator solenoid
valve electrical connector, as required.
- Remove the exhaust (1) camshaft position
(CMP) actuator solenoid valve bolt and valve, as required.
- Remove the intake (2) CMP actuator solenoid valve bolt and valve, as required.
- Inspect the solenoid valve O-ring seals from damage, replace as necessary.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Lubricate the solenoid valve O-ring seals
with clean engine oil.
- Install the intake (2) CMP actuator solenoid valve and bolt, as required.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Install the exhaust (1) CMP actuator solenoid valve and bolt, as required.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Connect the intake (3) or exhaust (2) camshaft
position actuator solenoid valve electrical connector, as required.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.