• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ | 1 | 1 | -- | -- |
Rear Defog Switch Signal | 2 | 1 | 1 | -- |
Rear Defog Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Rear Window Defogger Grid Control | 1 | 1 | 2 | -- |
Rear Defog Indicator Control | B0283 02 | B0283 05 | B0283 05 | -- |
HVAC Ground | -- | 1 | 1 | -- |
Relay Coil Ground | -- | 1 | 1 | -- |
Rear Window Defogger Grid Ground | -- | 1 | 1 | -- |
1. Rear defogger Inoperative 2. Rear Defogger Always ON |
Battery positive voltage is supplied through the REAR DEFOG fuse, in the underhood fuse block, to the REAR DEFOG relay switched input. The BCM supplies 12 volts on the rear window defogger switch signal circuit to the HVAC control module. When you depress the defog switch, the rear window defogger switch pulls the signal circuit low. The BCM interprets as a request for the rear window defogger system. The BCM enables the rear window defogger system by supplying voltage to the REAR DEFOG relay coil. The relay coil supply voltage is also spliced off internally in the BCM to the supply voltage circuit of the defogger indicator. The REAR DEFOG relay is energized and the defogger indicator is illuminated. With the relay energized, battery positive voltage is allowed from the relay switched input through the switch contacts and out the relay switched output to the rear window defogger grid.
Rear Window Defogger Description and Operation
Control Module References for scan tool information
⇒ | If the value does not change between the commanded states, refer to Rear Window Defogger Switch Malfunction. |
⇒ | If the rear window defogger does not turn ON and OFF when changing between the commanded states, refer to Rear Defogger Malfunction. |
⇒ | If the rear window defogger indicator is always ON or always OFF, refer to Rear Defogger Indicator Malfunction. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 3 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 30 for a short to ground. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the rear window defogger grid does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the rear window defogger grid. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, replace the HVAC control assembly. |
⇒ | If greater than the specified range, replace the HVAC control assembly. |
⇒ | If the defog indicator does not illuminate, replace the HVAC control assembly. |
⇒ | If the test lamp remains bright at the middle of the grid line, test for an open between the test point and the ground side of the grid. |
⇒ | If the test lamp remains off at the middle of the grid line, test for an open between the test point and the voltage supply side of the grid |
⇒ | If not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM and HVAC control assembly replacement, setup and programming |