Removal Procedure
- Remove the fuse labeled HVAC CTRL (BATT).
- Remove the instrument panel (I/P) retainer. Refer to
Instrument Panel Retainer Replacement
.
- Remove the I/P tie bar. Refer to
Instrument Panel Tie Bar Replacement .
- Disconnect the recirculation actuator electrical connector.
- Remove the recirculation actuator screw.
- Remove the recirculation actuator.
Installation Procedure
Important: The key should be in the OFF position when
connecting the electrical connectors to ensure proper calibration.
- Install the recirculation actuator.
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator screw.
Tighten
Tighten the screw to 2.2 N·m (19 lb in).
- Install the recirculation electrical connector.
- Install the I/P tie bar. Refer to
Instrument Panel Tie Bar Replacement .
- Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement
.
- Install the fuse labeled HVAC CTRL (BATT).
Important: Do not adjust any controls on the HVAC control
assembly while the HVAC control assembly and actuators are calibrating. If interrupted
improper HVAC performance will result.
- Start the engine and let run for 1 minute.