Brake Pressure Modulator Valve Replacement Without JL4
Callout
| Component Name
|
Caution: Refer to Brake Fluid Irritant Caution in the Preface section.
Notice: Always connect or disconnect the wiring harness connector from the EBCM/EBTCM
with the ignition switch in the OFF position. Failure to observe this precaution
could result in damage to the EBCM/EBTCM.
Preliminary Procedures
- Turn the ignition switch to the OFF position.
- Remove the cover from the engine control module (ECM) and the transmission control module (TCM).
- Clean the electronic brake control module (EBCM) to brake pressure modulator valve (BPMV) area and the brake pipe fitting areas of any accumulated dirt and foreign material.
|
1
| Electronic Brake Control Module (EBCM) Electrical Connector
Tip Lift the slide lock tabs to release the electrical connector from the EBCM. |
2
| Fitting, Brake Pipe (Qty: 6)
Notice: Refer to Fastener Notice in the Preface section.
Procedure
- Note the location of the brake pipes before removal to aid during installation.
- Cap the brake pipe ends and plug the pipe ports on the BPMV to prevent brake fluid loss and contamination.
Tighten 21 N·m (15 lb ft) |
3
| Brake Pressure Modulator Valve (BPMV) Bracket Bolt (Qty: 2)
Tip Loosen but do not remove the forward upper bolt.
Tighten 25 N·m (18 lb ft) |
4
| Brake Pressure Modulator Valve (BPMV)
Procedure
- If installing a new BPMV, remove the EBCM. Refer to
Electronic Brake Control Module Replacement
.
- If installing a new BPMV, remove the bracket from the BPMV. Refer to
Brake Pressure Modulator Valve Bracket Replacement
.
- If installing a new BPMV, install new EBCM to BPMV O-ring seals.
- Bleed the hydraulic brake system. Refer to
Hydraulic Brake System Bleeding
.
- Perform the
Diagnostic System Check - Vehicle
.
- Observe brake pedal feel after performing the diagnostic system check. If the pedal now feels spongy, air may have been in the secondary hydraulic circuit of the brake modulator which may have been introduced into the primary circuit. If the pedal
feels spongy, perform the
Antilock Brake System Automated Bleed Procedure
.
|
Brake Pressure Modulator Valve Replacement With JL4, LNF
Caution: Refer to Brake Fluid Irritant Caution in the Preface section.
Removal Procedure
Notice: Always connect or disconnect the wiring harness connector from the EBCM/EBTCM
with the ignition switch in the OFF position. Failure to observe this precaution
could result in damage to the EBCM/EBTCM.
- Turn the ignition switch to the OFF position.
- Release the charge air cooler inlet pipe from the bracket and position aside without removing the charge air cooler inlet pipe.
- Remove the transmission control module (TCM) from the bracket and position aside.
- Clean the brake pressure modulator valve (BPMV) brake pipe fitting area of any accumulated dirt and foreign material.
- Disconnect the electronic brake control module (EBCM) electrical connector.
- Disconnect the master cylinder primary brake pipe fitting (1).
Cap the fitting and plug the BPMV inlet port to
prevent brake fluid loss and contamination.
- Disconnect the master cylinder secondary brake pipe fitting (1).
Cap the fitting and plug
the BPMV inlet port to prevent brake fluid loss and contamination.
- Disconnect the LF brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the RF brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the RR brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the LR brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Remove the BPMV bolt (1).
Important: Do not remove the mounting pins unless it is necessary to aid in releasing the modulator assembly from the bracket.
- Carefully remove the BPMV assembly from the BPMV bracket insulators by pulling straight upward.
Do not pry against the accumulator covers on the underside of the brake modulator assembly to release the mounting pins from the bracket insulators.
Installation Procedure
- Install the BPMV assembly to the BPMV bracket until the mounting pins are fully inserted in the bracket insulators.
Notice: Refer to Fastener Notice in the Preface section.
- Install the BPMV bolt (1).
Tighten
Tighten the bolt to 11 N·m (97 lb in).
- Connect the LR brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the RR brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the RF brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the LF brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the master cylinder secondary brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the master cylinder primary brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the EBCM electrical connector.
- Install the TCM to the bracket.
- Position the charge air cooler inlet pipe to the bracket.
- Program the EBCM. Refer to
Electronic Brake Control Module Programming and Setup.
- Bleed the hydraulic brake system. Refer to
Hydraulic Brake System Bleeding.
- Perform the
Diagnostic System Check - Vehicle.
- Observe the brake pedal feel after performing the diagnostic system check. If the pedal now feels spongy, air may have been in the secondary hydraulic circuit of the brake modulator which may have been introduced into the primary circuit. If the
pedal feels spongy, perform the
Antilock Brake System Automated Bleed Procedure.
Brake Pressure Modulator Valve Replacement With JL4
Caution: Refer to Brake Fluid Irritant Caution in the Preface section.
Removal Procedure
Notice: Always connect or disconnect the wiring harness connector from the EBCM/EBTCM
with the ignition switch in the OFF position. Failure to observe this precaution
could result in damage to the EBCM/EBTCM.
- Turn the ignition switch to the OFF position.
- Remove the cover from the engine control module (ECM) and the transmission control module (TCM).
- Clean the electronic brake control module (EBCM) to brake pressure modulator valve (BPMV) area and the brake pipe fittings of any accumulated dirt and foreign material.
- Disconnect the EBCM electrical connector.
- Disconnect the master cylinder primary brake pipe fitting (1).
Cap the fitting and plug the BPMV inlet port to
prevent brake fluid loss and contamination.
- Disconnect the master cylinder secondary brake pipe fitting (1).
Cap the fitting and plug
the BPMV inlet port to prevent brake fluid loss and contamination.
- Disconnect the LF brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the RF brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the RR brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Disconnect the LR brake pipe fitting (1).
Cap the fitting and plug the BPMV outlet port
to prevent brake fluid loss and contamination.
- Remove the BPMV bolt (1).
Important: Do not remove the mounting pins unless it is necessary to aid in releasing the modulator assembly from the bracket.
- Carefully remove the BPMV assembly from the BPMV bracket insulators by pulling straight upward.
Do not pry against the accumulator covers on the underside of the brake modulator assembly to release the mounting pins from the bracket insulators.
- If installing a new BPMV, remove the EBCM. Refer to
Electronic Brake Control Module Replacement.
Installation Procedure
- If installing a new BPMV, install the EBCM. Refer to
Electronic Brake Control Module Replacement.
- Install the BPMV assembly to the BPMV bracket until the mounting pins are fully inserted in the bracket insulators.
Notice: Refer to Fastener Notice in the Preface section.
- Install the BPMV bolt (1).
Tighten
Tighten the bolt to 11 N·m (97 lb in).
- Connect the LR brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the RR brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the RF brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the LF brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the master cylinder secondary brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the master cylinder primary brake pipe fitting (1).
Tighten
Tighten the fitting to 21 N·m (15 lb ft).
- Connect the EBCM electrical connector.
- Install the cover to the ECM and the TCM.
- Bleed the hydraulic brake system. Refer to
Hydraulic Brake System Bleeding.
- Program the EBCM. Refer to
Service Programming System (SPS).
- Perform the
Diagnostic System Check - Vehicle.
- Observe the brake pedal feel after performing the diagnostic system check. If the pedal now feels spongy, air may have been in the secondary hydraulic circuit of the brake modulator which may have been introduced into the primary circuit. If the
pedal feels spongy, perform the
Antilock Brake System Automated Bleed Procedure.