• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Courtesy Lamps Control | 1 | 1 | -- | -- |
Courtesy Lamps Low Control | 1 | B2555 05 | B2555 05 | -- |
Park Lamp Control | 3 | 3 | 3 | -- |
Dome Lamp Ground | -- | 2 | -- | -- |
I/P Dimmer Switch Ground | -- | 1 | -- | -- |
Inside Rearview Mirror Ground | -- | 1 | -- | -- |
1. Courtesy Lamps Malfunction 2. Dome Lamps Malfunction 3. Park, License, and/or Tail Lamps Malfunction |
The body control module (BCM) applies battery voltage to the courtesy lamps through the courtesy lamps control circuit. When any door is opened, the door ajar switch contacts close and the BCM receives a door-open input. If the BCM receives a door lock or unlock input or a rear hatch open input, the BCM will activate the courtesy lamps control circuit, providing battery voltage to all of the dome lamps and reading lamps. The dome lamps are provided with battery voltage via the courtesy lamps control circuit and ground through the courtesy lamps low control circuit. In the event that any of these lamps were to remain illuminated for more than 20 minutes with the ignition switch in the OFF position, the BCM will deactivate the courtesy lamp high control circuit to prevent a total battery discharge condition.
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the courtesy lamps do not illuminate when commanded, refer to Illuminated Entry Lamps Malfunction. |
⇒ | If the parameter does not change as the driver door is opened and closed, refer to Door Ajar Indicator Malfunction. |
⇒ | If the parameter does not change as each door is opened and closed , refer to Door Ajar Indicator Malfunction. |
⇒ | If the reading does not change as the liftgate is opened and closed, refer to Liftgate Ajar Indicator Malfunction. |
⇒ | If the reading lamps do not turn ON and OFF, refer to Reading Lamps Malfunction. |
• | Dome lamp ground terminal A |
• | Inside rearview mirror ground terminal 8 - with UE1 |
• | Inside rearview mirror low control terminal 2 - without UE1 |
• | Dome lamp control terminal D |
• | Inside rearview mirror control terminal 6 - with UE1 |
• | Inside rearview mirror control terminal 7 - without UE1 |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
• | Dome lamp low control terminal B |
• | Inside rearview mirror low control terminal 1 - with UE1 |
• | Inside rearview mirror low control terminal 6 - without UE1 |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
• | Dome lamp ground terminal A |
• | Inside rearview mirror ground terminal 8 - with UE1 |
• | Inside rearview mirror low control terminal 2 - without UE1 |
⇒ | If greater than the specified value, test the ground circuit for an open/high resistance. |
• | Dome lamp control terminal D |
• | Inside rearview mirror control terminal 6 - with UE1 |
• | Inside rearview mirror control terminal 7 - without UE1 |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the courtesy lamps remain illuminated, test the control circuit terminal A for a short to ground. |
⇒ | If the courtesy lamps do not illuminate, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |