Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-234 kPa (22-34 psi) | 709-1123 kPa (103-163 psi) | 12°C (52°F) |
19-24°C (66-75°F) | Below 40% | 151-241 kPa (22-35 psi) | 930-1378 kPa (135-200 psi) | 12°C (52°F) |
Above 40% | 158-282 kPa (23-41 psi) | 978-1446 kPa (142-210 psi) | 14°C (57°F) | |
25-29°C (76-85°F) | Below 35% | 172-268 kPa (25-39 psi) | 1260-1639 kPa (183-238 psi) | 13°C (55°F) |
35-50% | 172-282 kPa (25-41 psi) | 1240-1667 kPa (180-242 psi) | 15°C (59°F) | |
Above 50% | 206-310 kPa (30-45 psi) | 1322-1729 kPa (192-251 psi) | 18°C (63°F) | |
30-35°C (86-95°F) | Below 30% | 206-310 kPa (30-45 psi) | 1522-1942 kPa (221-282 psi) | 18°C (63°F) |
30-50% | 227-323 kPa (33-47 psi) | 1550-1991 kPa (225-289 psi) | 18°C (63°F) | |
Above 50% | 241-351 kPa (35-51 psi) | 1591-2060 kPa (231-299 psi) | 22°C (55°F) | |
36-41°C (96-105°F) | Below 20% | 248-344 kPa (36-50 psi) | 1818-2239 kPa (264-325 psi) | 19°C (66°F) |
20-40% | 261-358 kPa (38-52 psi) | 1839-2287 kPa (267-332 psi) | 22°C (70°F) | |
Above 40% | 275-385 kPa (40-56 psi) | 1887-2342 kPa (274-340 psi) | 23°C (73°F) | |
42-46°C (106-115°F) | Below 20% | 296-378 kPa (43-55 psi) | 1887-2342 kPa (274-340 psi) | 23°C (73°F) |
Above 20% | 303-392 kPa (44-57 psi) | 2129-2501 kPa (309-363 psi) | 23°C (72°F) | |
47-49°C (116-120°F) | Below 30% | 337-420 kPa (49-61 psi) | 2418-2790 kPa (351-405 psi) | 27°C (79°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-241 kPa (22-35 psi) | 1102-1481 kPa (160-215 psi) | 12°C (52°F) |
19-24°C (66-75°F) | Below 40% | 158-261 kPa (23-38 psi) | 1212-1598 kPa (176-232 psi) | 13°C (54°F) |
Above 40% | 179-303 kPa (26-44 psi) | 1288-1701 kPa (187-247 psi) | 15°C (59°F) | |
25-29°C (76-85°F) | Below 35% | 199-296 kPa (29-43 psi) | 1460-1777 kPa (212-258 psi) | 14°C (57°F) |
35-50% | 220-310 kPa (32-45 psi) | 1508-1812 kPa (219-263 psi) | 17°C (61°F) | |
Above 50% | 234-351 kPa (34-51 psi) | 1550-1887 kPa (225-274 psi) | 19°C (66°F) | |
30-35°C (86-95°F) | Below 30% | 227-330 kPa (33-48 psi) | 1646-1991 kPa (239-289 psi) | 18°C (63°F) |
30-50% | 248-358 kPa (36-52 psi) | 1681-2039 kPa (244-296 psi) | 20°C (68°F) | |
Above 50% | 268-399 kPa (39-58 psi) | 1729-2108 kPa (251-306 psi) | 23°C (73°F) | |
36-41°C (96-105°F) | Below 20% | 261-351 kPa (38-51 psi) | 1860-2197 kPa (270-319 psi) | 19°C (66°F) |
20-40% | 275-385 kPa (40-56 psi) | 1887-2239 kPa (274-325 psi) | 23°C (72°F) | |
Above 40% | 303-420 kPa (44-61 psi) | 1942-2287 kPa (282-332 psi) | 25°C (77°F) | |
42-46°C (106-115°F) | Below 20% | 296-385 kPa (43-56 psi) | 2087-2390 kPa (303-347 psi) | 22°C (70°F) |
Above 20% | 316-427 kPa (46-62 psi) | 2122-2432 kPa (308-353 psi) | 25°C (77°F) | |
47-49°C (116-120°F) | Below 30% | 344-440 kPa (50-64 psi) | 2308-2597 kPa (335-377 psi) | 27°C (79°F) |