GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0645: Air Conditioning (A/C) Clutch Relay Control Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

A/C CLUTCH Relay Switch B+

2

2

--

--

A/C CLUTCH Relay Coil Ignition

2

2

--

--

A/C CLUTCH Relay Control

P0645

P0645

P0645

--

A/C Clutch Control

2

2

1

--

A/C Compressor Clutch Ground

--

2

2

--

1. A/C Clutch Always Engaged

2. A/C Clutch Inoperative

Circuit/System Description

When the A/C switch is pressed, the HVAC control assembly sends a serial data message to the engine control module (ECM) for an A/C request. This input will request the ECM to ground the A/C compressor clutch relay control circuit, which will switch the A/C CLTCH relay. With the relay contacts closed, battery voltage is supplied to the A/C compressor clutch assembly.

Conditions for Running the DTC

    • The ignition voltage is between 9 and 18 volts.
    • The engine speed is more than 600 RPM.
    • An A/C request is made.

Conditions for Setting the DTC

    • A short to ground on the A/C compressor clutch relay control circuit.
    • A short to voltage on the A/C compressor clutch relay control circuit.
    • An open circuit on the A/C compressor clutch relay control circuit or relay.
    • An internally shorted or excessively low resistance A/C clutch relay coil.

Action Taken When the DTC Sets

    • The A/C clutch relay is commanded OFF.
    • The conditions for which the DTC was set will be stored in the Failure Records data only. No information will be stored as Freeze Frame data.

Conditions for Clearing the DTC

The history DTC will clear after 40 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

    •  Air Temperature Description and Operation
    •  Air Delivery Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Ignition OFF, disconnect the A/C CLUTCH relay.
  2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 86 and ground.
  3. If the test lamp illuminates, test the control circuit for a short to voltage.
  4. Verify that a test lamp illuminates between the ignition circuit terminal 85 and ground.
  5. If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and ignition circuit fuse is open, test or replace the relay.
  6. Connect a test lamp between the ignition circuit terminal 85 and the control circuit terminal 86.
  7. Command the A/C relay ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  8. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
    If the test lamp is always OFF, test the control circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace the ECM.
  9. If all circuits test normal, test or replace the A/C CLUTCH relay.

Component Testing

  1. Ignition OFF, disconnect the A/C CLUTCH relay.
  2. Test for 60-180 ohms between terminals 85 and 86.
  3. If the resistance is not within the specified range, replace the relay.
  4. Test for infinite resistance between the following terminals:
  5. • 30 and 86
    • 30 and 87
    • 30 and 85
    • 85 and 87
    If not the specified value, replace the relay.
  6. Install a 30-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Test for less than 2 ohms between terminals 30 and 87.
  7. If greater than the specified range, replace the relay.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Relay Replacement
    •  Control Module References for ECM replacement, setup, and programming