GM Service Manual Online
For 1990-2009 cars only

Info - Proper Service of Quick Connect EVAP System Connectors

Subject:Proper Service Of Quick Connect EVAP System Connectors

Models:1985-2001 Passenger Cars and Trucks



The EVAP system must be serviced properly. Improper service of the EVAP system can cause EVAP system leaks and set an engine DTC.

Important: DO NOT cut or kink EVAP hoses/pipes to service the EVAP system. A damaged, cut or kinked EVAP system hose/pipe must be replaced and NOT REPAIRED.

To properly service the EVAP system, it is important to correctly identify the style of quick connect EVAP fitting used in the EVAP system. Correctly identifying the style of fitting will aid in the proper disconnection/connection of the fitting and the ability to reuse the fitting.

Improper disconnection and/or connection of EVAP fittings can cause the following conditions and set engine DTCs:

    • Leaks in the EVAP system
    • Damage to the EVAP fitting(s)
    • Damage to and/or adversely effect the function of the EVAP components such as:
       - Purge solenoid
       - Canister
       - Vapor lines

STYLE A


    Object Number: 697137  Size: SH
  1. To properly disconnect this style of fitting, slide the tab in and pull the fittings apart.
  2. To reconnect this style of fitting, install the fittings back together and gently pull back on the fittings to verify proper connection of the fittings.

STYLE B


    Object Number: 697138  Size: SH
  1. To properly disconnect this style of fitting, push in both sides of the retaining feature and pull the fittings apart.
  2. To reconnect this style of fitting, install the fittings back together and gently pull back on the fittings to verify proper connection of the fittings.

STYLE C


Object Number: 697141  Size: SH

To properly disconnect this style of fitting, use the following procedure:


    Object Number: 697144  Size: SH
  1. Move the tab of the retainer away from the male fitting in order to clear the retaining nub.

  2. Object Number: 697148  Size: SH
  3. Move the tab of the retainer in the direction shown and pull the fittings apart.
  4. To reconnect this style of fitting, install the fittings back together and gently pull back on the fittings to verify proper connection of the fittings.

STYLE D


Object Number: 697151  Size: SH

To properly service this style of fitting use the following procedure:


    Object Number: 697152  Size: SH
  1. Push in both tabs of the retainer.

  2. Object Number: 697154  Size: SH
  3. Pull the female fitting away from the male fitting.

  4. Object Number: 697158  Size: SH
  5. Remove and discard the retainer fitting from the male fitting.

  6. Object Number: 697161  Size: SH
  7. Remove and discard the indicator ring (factory use only) from the male fitting.

  8. Object Number: 697163  Size: SH
  9. Install a NEW retainer fitting into the female fitting.

  10. Object Number: 697166  Size: SH
  11. Connect the fittings together until a snap is heard and/or felt signifying the retainer tabs have engaged the raised feature of the male fitting.

  12. Object Number: 697169  Size: SH
  13. Gently pull back on the fittings to verify proper connection of the fittings.