Removal Procedure


    Object Number: 405812  Size: SH
  1. Remove the oil level indicator.
  2. Loosen the nut holding the oil level indicator tube bracket to the exhaust manifold stud.
  3. Remove the oil level indicator tube. Pull upward.

Installation Procedure


    Object Number: 405812  Size: SH
  1. Install the oil indicator tube to the engine. Make sure that the O-ring is in place. Make sure that the oil level indicator tube is fully seated in the engine.
  2. Slide the oil indicator tube bracket onto the exhaust manifold stud.
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the oil level indicator tube bracket nut on the exhaust manifold stud.
  5. Tighten
    Tighten the oil level indicator tube bracket nut to 19 N·m (14 lb ft).

  6. Install the oil level indicator.