Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Do all of the turn signal tamps flash on and off? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Inspect the Hazard Switch Fuse. Is the fuse open? | Go to Step 4 | Go to Step 5 |
4 | Repair a short to ground in the hazard switch fuse B+ circuit feed. Did you complete the repair? | Go to Step 8 | -- |
5 | Disconnect the hazard lamp/turn signal lamp flasher. Using a test lamp connected to a known good ground, probe the hazard switch fuse B+ circuit. Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
6 | Repair a poor connection or an open in the hazard switch fuse B+ circuit. Did you complete the repair? | Go to Step 8 | -- |
7 | Replace the hazard lamp/turn signal lamp flasher. Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 |