Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Are the fog lamps on and the fog lamp indicator on? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Using a test lamp connected to a known good ground, backprobe the fog lamp switch B+ feed circuit. Does the test lamp turn on? | Go to Step 5 | Go to Step 4 |
4 | Repair a poor connection or an open in the fog lamp switch B+ feed circuit. Is the repair complete? | Go to Step 6 | -- |
5 | Replace the fog lamp switch. Refer to Fog Lamp Switch Replacement . Is the repair complete? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Is the repair complete? | Go to Step 2 |