Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Are both of the fog lamps on? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Using a test lamp connected to a known good ground, backprobe the inoperable fog lamp B+ feed circuit. Does the test lamp turn on? | Go to Step 5 | Go to Step 4 |
4 | Repair a poor connection or an open in the fog lamp B+ feed circuit. Is the repair complete? | Go to Step 8 | -- |
5 | Using a test lamp, backprobe between the inoperable fog lamp B+ feed circuit and the inoperable fog lamp ground circuit. Does the test lamp turn on? | Go to Step 6 | Go to Step 7 |
6 | Replace the inoperable fog lamp. Refer to Front Fog Lamp Replacement . Is the repair complete? | Go to Step 8 | -- |
7 | Repair a poor connection or an open in the fog lamp ground circuit. Is the repair complete? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Is the repair complete? | Go to Step 2 |