Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems. |
2 |
Do the turn signal tamps flash on and off? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Using a test light conected to a good B+ feed circuit, probe the hazard lamp/turn signal lamp flasher ground circuit. Does the test lamp illuminate? | Go to Step 5 | Go to Step 4 |
4 | Repair a poor conection or an open in the hazard lamp/turn signal lamp flasher ground circuit. Did you complete the repair? | Go to Step 6 | -- |
5 | Replace the hazard lamp/turn signal flasher. Did you complete the repair? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | Go to Step 2 |