Removal Procedure
- Remove the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.
- Lift the recirculation actuator lock tab and slide the recirculation
actuator off the mounting bracket.
- Disconnect the vacuum actuator plunger rod from the recirculation
lever and remove the recirculation actuator.
- Remove the recirculation housing retaining screws (1).
- Remove the recirculation housing (2) from the HVAC module
assembly.
- Remove the recirculation
door (1) from the recirculation housing (2).
Installation Procedure
- Install the recirculation
door.
- Align the retaining tabs and install the recirculation housing (2)
to the HVAC module assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the recirculation housing screws.
Tighten
Tighten the recirculation housing screws to 1.5 N·m (13 lb in).
- Connect the recirculation actuator plunger rod to the recirculation
door lever, then extend the plunger.
- Install the recirculation actuator on to the mounting bracket
of the HVAC assembly.
Important: Inspect the recirculation actuator pushrod for binding on the recirculation
door lever.
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.