Removal Procedure
- Remove the right side instrument panel (IP) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages, and Console.
- Remove the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the electrical
connector from the right air temperature actuator.
- Remove the screws retaining
the right air temperature actuator.
- Remove the right air temperature actuator.
Installation Procedure
- Position the right air
temperature actuator. Align the slots in the electric actuator driver to
the flats on the shaft.
- Align the locating hole to the alignment pin on the HVAC module
case.
- Slide the actuator on the shaft. The actuator driver should seat
completely onto the shaft and the mounting holes should be flush with the
mounting screws on the HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the right air temperature actuator.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the right air temperature actuator.
- Install the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Install the right side IP insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gages, and Console.