GM Service Manual Online
For 1990-2009 cars only

    Object Number: 36667  Size: SH

    Important: Inspect the EGR inlet/outlet pipes for leaks before installation. If cracks, deformations or any visible signs of leaking are present, replace the appropriate part.

  1. Install the EGR inlet pipe into the RH exhaust manifold as the EGR valve adapter assembly is installed onto the cylinder head.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the EGR valve adapter assembly to cylinder head bolts and the EGR inlet pipe to RH exhaust manifold bolt.
  4. Tighten

        • Tighten the EGR valve adapter assembly to cylinder head bolts to 50 N·m (37 lb ft).
        • Tighten the EGR inlet pipe to RH exhaust manifold bolt to 29 N·m (21 lb ft).
  5. Install the EGR valve outlet pipe to the lower intake and the EGR valve adapter assembly.
  6. Install the EGR valve outlet pipe bolt and nut.
  7. Tighten
    Tighten the EGR valve outlet pipe bolt and nut to 29 N·m (21 lb ft).

  8. Install the EGR valve gasket and EGR valve.
  9. Install the EGR valve nuts.
  10. Tighten
    Tighten the EGR valve nuts to 29 N·m (21 lb ft).


    Object Number: 97747  Size: SH
  11. Install the lower right exhaust manifold heat shield.

  12. Object Number: 97750  Size: SH
  13. Install the upper right exhaust manifold heat shield.

  14. Object Number: 395584  Size: SH
  15. Install the heated oxygen sensor lead.