Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The number(s) below refer to the step number(s) on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? | Above 16°C (60°F) - 345 kPa (50 psi) Above 24°C (75°F) - 483 kPa (70 psi) Above 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature AT THE TIME OF THE TEST.
Important: When performing this step it is necessary to press the RESET button on the J 43600 before pressing the PRINT button.
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure is within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 175-239 kPa (25-35 psi) | 920-1360 kPa (133-197 psi) | 11°C (51.8°F) |
18-24°C (65-75°F) | Below 40% | 175-225 kPa (25-33 psi) | 940-1360 kPa (136-197 psi) | 9°C (48.2°F) |
Above 40% | 175-256 kPa (25-37 psi) | 1080-1480 kPa (157-215 psi) | 12°C (53.6°F) | |
24-29°C (75-85°F) | Below 35% | 175-238 kPa (25-35 psi) | 1200-1510 kPa (174-219 psi) | 11°C (51.8°F) |
35-50% | 181-246 kPa (26-36 psi) | 1260-1540 kPa (183-224 psi) | 11°C (58.1°F) | |
Above 50% | 192-262 kPa (27-38 psi) | 1310-1580 kPa (190-229 psi) | 12°C (53.6°F) | |
29-35°C (85-95°F) | Below 30% | 188-258 kPa (27-37 psi) | 1400-1720 kPa (203-250 psi) | 12°C (53.6°F) |
30-50% | 196-262 kPa (28-38 psi) | 1420-1720 kPa (206-250 psi) | 13°C (55.4°F) | |
Above 50% | 206-268 kPa (30-40 psi) | 1460-1720 kPa (212-250 psi) | 13°C (55.4°F) | |
35-41°C (95-105°F) | Below 20% | 214-282 kPa (31-41 psi) | 1640-1950 kPa (238-283 psi) | 14°C (57.2°F) |
20-40% | 216-282 kPa (31-41 psi) | 1640-1950 kPa (238-283 psi) | 14°C (57.2°F) | |
Above 40% | 220-282 kPa (32-41 psi) | 1640-1950 kPa (238-283 psi) | 14°C (57.2°F) | |
41-46°C (105-115°F) | Below 20% | 243-303 kPa (35-44 psi) | 1890-2140 kPa (274-311 psi) | 16°C (60.8°F) |
Above 20% | 242-303 kPa (35-44 psi) | 1890-2140 kPa (274-311 psi) | 16°C (60.8°F) | |
46-49°C (115-120°F) | Below 30% | 263-310 kPa (38-45 psi) | 2060-2210 kPa (299-321 psi) | 17°C (62.6°F) |