Removal Procedure
- Remove the left instrument panel (I/P) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument
Panel, Gages, and Console.
- Remove the knee bolster bracket bracket. Refer to
Driver Knee Bolster Bracket Replacement
or to
Passenger Knee Bolster Bracket Replacement
in Instrument Panel, Gages, and
Console.
- Disconnect the electrical connector from the left air temperature actuator.
- Remove the mounting screws from the left air temperature actuator.
- Remove
the left air temperature actuator.
Installation Procedure
- Position
the left air temperature actuator. Align the slots in the electric actuator driver
to the flats on the shaft.
- Align the locating hole to the alignment pin on the HVAC module case.
- Slide the actuator on the shaft. The actuator driver should seat completely
onto the shaft and the mounting holes should be flush with the mounting screws on
the HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting screws to the left air temperature actuator.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the left air temperature actuator.
- Install the knee bolster bracket bracket. Refer to
Driver Knee Bolster Bracket Replacement
or to
Passenger Knee Bolster Bracket Replacement
in Instrument Panel, Gages, and
Console.
- Install the left I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages, and Console.
- Calibrate the actuator. Refer to
Actuator Recalibration
in HVAC Systems - Manual.