• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ | 2 | 2 | -- | -- |
Rear Defog Relay Control | B0283 06 | B0283 05 | B0283 05 | -- |
Rear Window Defogger Grid Control | 2 | 2 | 1 | -- |
Relay Coil Ground | -- | B0283 05 | 2 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
1. Rear defogger always On 2. Rear defogger inoperative |
When the rear defogger button is pressed, voltage is supplied to the relay coil and the HVAC control module also illuminates the rear window defogger indicator. Battery positive voltage is supplied at all times to the relay switched input and the relay coil is always grounded. This allows battery positive voltage from the relay switched input through the switch contacts and out the relay switched output to the rear window defogger.
Rear Window Defogger Description and Operation
Control Module References for scan tool information
⇒ | If the parameter does not change between the commanded states, replace the HVAC module. |
⇒ | If the indicator does not turn ON or OFF with each switch press, replace the HVAC module. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the defogger grid does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the defogger grid. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
⇒ | If the test lamp remains bright at the middle of the grid line, test for an open between the test point and the ground side of the grid. |
⇒ | If the test lamp remains off at the middle of the grid line, test for an open between the test point and the voltage supply side of the grid |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup and programming |