Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B0158 13: Outside Air Temperature Sensor Circuit Voltage low

DTC B0158 14: Outside Air Temperature Sensor Circuit Voltage high

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Ambient Air Temperature Sensor Signal

B0158 13

B0158 13

B0158 14

B0158 13,14

Low Reference

--

B0158 14

B0158 13

B0158 13,14

Circuit/System Description

The HVAC control module supplies the ambient air temperature sensor with a low reference circuit and 5-volt signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. As the air temperature increases, the sensor resistance decreases and the voltage signal decreases. As the air temperature decreases, the sensor resistance increases and the voltage signal increases.

Conditions for Running the DTC

The ignition is turned ON.

Conditions for Setting the DTC

The HVAC control module detects the ambient air temperature sensor signal circuit is less than -36°C (-38°F) or more than 215°C (419°F) for more than 15 seconds.

Action Taken When the DTC Sets

    • The HVAC control module will display dashes for outside air temperature.
    • The DIC will display SERVICE A/C SYSTEM.
    • The system operates using a default value.

Conditions for Clearing the DTC

    • The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.
    • The history DTC will clear after 50 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

    •  Air Delivery Description and Operation
    •  Air Temperature Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

Important: An instant OAT update must be performed by pressing the A/C and Recirc buttons at the same time after the system has been repaired to convert the A/C permission from out of range to normal.

  1. Ignition OFF, disconnect the harness connector at the outside air temperature sensor.
  2. Ignition OFF, test for less than 10 ohms of resistance between the low reference circuit terminal B and ground.
  3. If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  4. Ignition ON, verify the scan tool Ambient Air Temperature sensor parameter is less than -35°F (-37°C).
  5. If greater than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
  6. Install a 3A fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Ambient Air Temperature sensor parameter is greater than 180°F (82°C).
  7. If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  8. If all circuits test normal, test or replace the ambient air temperature sensor.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Ambient Air Temperature Sensor Replacement
    •  Control Module References for HVAC control module replacement, setup and programming