• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The engine control module (ECM) commands the fans ON in high speed or low speed. In low speed, the fans are configured in series. In high speed, the fans are configured in parallel.
In low speed operation, the ECM applies ground to the coil side of the low fan speed fan relay, which is the Fan 1 Relay. Voltage is applied directly to the left cooling fan through the switch side of the low speed fan relay. The right fan is connected in series to the left fan through the de-energized Series/Parallel relay, which is Fan 2 Relay, so that both fans operate at low speed.
In high speed operation, the ECM applies a ground to the coil side of the low fan speed fan relay, the Series/Parallel relay, and the high speed fan relay, which is the Fan 3 Relay. Voltage is applied directly to the right cooling fan through the switch side of the high speed fan relay. The left cooling fan obtains voltage through the low speed fan relay and ground through the Series/Parallel relay.
When the ECM is commanding a fan relay ON, the voltage of the control circuit should be low, near 0 volts. When the ECM is commanding a fan relay OFF, the voltage of the control circuit should be high, near battery voltage.
Cooling Fan Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
⇒ | If the fan is activated, test the left fan ground circuit for a short to ground. |
⇒ | If the appropriate fan does not activate, test the fan voltage supply circuit for a short to ground or open/high resistance. If the circuit tests normal, test the fan ground circuit for an open/high resistance. If the circuits test normal, replace the fan. |
⇒ | If the fan does not activate, test the relay switch voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and its fuse is open, test all connected components and replace as necessary. |
• | Control Module References for ECM replacement, setup, and programming |
Ignition ON, command each relay ON and OFF with a scan tool. Observe to verify that the fans turn ON and OFF with each command.