Note: The lifter oil manifold assembly (LOMA) connector must be disconnected from the lower intake manifold before removing the lower intake manifold.
Note: Do not allow dirt or debris to enter the oil passages of the manifold. Plug as required.
Note:
• All gasket surfaces should be free of oil or other foreign material during assembly. • Do not allow dirt or debris to enter the oil passages of the manifold. Plug as required. • Do not reuse the manifold gasket. Always install a NEW service gasket during assembly. • Do not reuse the LOMA oil manifold filter. Always install a NEW filter during assembly.
Caution: Refer to Fastener Caution in the Preface section.
Tighten
Tighten the manifold bolts to 25 N·m (18 lb ft).
Note: The lifter oil manifold assembly (LOMA) connector must be disconnected from the lower intake manifold before installing the lower intake manifold.