Object Number: 1614155  Size: MF

Callout

Component Name

Preliminary Procedure

  1. Remove the HVAC module. Refer to HVAC Module Assembly Replacement.
  2. Disconnect the electrical connector from the recirculation actuator.

1

Air Inlet Assembly Screw (Qty: 3)

Caution: Refer to Fastener Caution in the Preface section.

Tighten
1.5 N·m (13 lb in)

2

Recirculation Actuator Screw (Qty: 2)

Tighten
1.5 N·m (13 lb in)

3

Recirculation Actuator

4

Air Inlet Housing Assembly