Removal Procedure
- Install a 1/2 inch breaker bar into the tensioner opening and rotate the
tensioner counterclockwise.
- Remove the belt from the tensioner.
- Slowly release the tension on the tensioner arm.
- Remove the drive belt from the drive pulleys , if equipped with a single generator.
- Remove the drive belt from the drive pulleys, if equipped with dual generators.
- Inspect the drive belt for excessive cracking or any visible damage and replace if necessary.
Installation Procedure
- Install a 1/2 inch breaker bar into the tensioner opening and rotate the
tensioner counterclockwise.
- Install the drive belt, if equipped with dual generators.
- Route the drive belt over and/or around all the drive pulleys except for the tensioner.
- Install the drive belt, if equipped with a single generator.
- Route the drive belt over and/or around all the drive pulleys except for the tensioner.
- Install the belt over and/or around the tensioner.
- Slowly release the tension on the tensioner arm.
- Inspect the drive belt for proper installation on and/or around all pulleys.