- Install the following
primary regulator valve components:
- Install the following
TCC lock-up control valve components:
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the following shift solenoid components:
• | The intermediate coast modulator valves (5) |
• | The intercoast modulator valve spring (2) |
• | The low coast modulator valve spring (6) |
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Install a new O-ring (2)
to the TCC solenoid.
- Lubricate the new O-ring with A/T fluid.
- Install the TCC solenoid (1).
- Install the TCC solenoid bolt.
Tighten
Tighten the bolt to 5 N·m (44 lb in).
- Install the following
pressure relief valve components:
Tighten
Tighten the bolt to 5 N·m (44 lb in).
- Install the following
TCC lock-up control valve plate components:
Tighten
Tighten the bolts to 5 N·m (44 lb in).
- Install the following lower valve body plate components:
Tighten
Tighten the bolts to 5 N·m (44 lb in).
- Install the following components to the valve body:
• | The valve body ball (2) |
• | The valve dampening spring |
• | The bypass valve spring |