Tools Required
• | J 43764 Torque Converter
End Play Gauge |
• | J 5959 Dial Indicator
Clamp and Adjuster |
• | J 7872 Magnetic Base
Dial Indicator |
- Position the torque converter (3)
on the work table so that the pump hub is facing up.
- Install J 43764
(2)
into the torque converter hub.
- Hold J 43764
(2)
in the converter hub and rotate the center screw until J 43764
is locked into the converter hub. Do not over tighten J 43764
.
- Assemble the following tools and install the tools onto the torque converter
as shown:
- Adjust the clamp (6) so that the dial indicator (1) firmly
contacts the top of J 43764
(2).
- Set the J 5959
(1)
to read zero.
- Lift J 43764
(2)
upward as far as possible.
- Read the J 5959
(1)
to determine torque converter end play.
- Compare the measured end play with the torque converter end play specifications.
Refer to
End Play Specifications
.
- If the measured torque converter end play exceeds the value listed, replace
the torque converter.
- Remove the J tools from the converter housing.