Table 1: | Supplemental Inflatable Restraint Scan Tool Data Parameters |
Table 2: | Supplemental Inflatable Restraint Scan Tool Output Controls |
Parameter | System State | Expected Value | Description |
---|---|---|---|
Operating Conditions: Ignition ON | |||
Active Switch | -- | Inactive | The scan tool displays Inactive or Active. This is the state of the SIR active switch. |
ADS A/D | -- | Varies | The scan tool displays volts. |
ADS Monitoring | -- | Not Present | The scan tool displays Present and Not Present. This is the current status of the ADS monitoring. |
Battery Voltage Signal | -- | Varies | This displays volts. This is the voltage input supplied to the SDM. |
Driver Frontal Stage 1 Loop | -- | Not Present | The scan tool displays Present and Not Present. This is the status of the driver frontal stage loop. |
Driver Side Loop | -- | Not Present | The scan tool displays Present and Not Present. This is the current status of the driver side loop. |
Psgr. Frontal Stage 1 Loop | -- | Not Present | The scan tool displays Present and Not Present. This is the status of the passenger frontal stage loop. |
Passenger Side Loop | -- | Not Present | The scan tool displays Present and Not Present. This is the current status of the passenger side loop. |
Output Control | Description |
---|---|
Setup New SDM | This output control is used to set up a new SDM. |
Setup SDM Part Number in IPC | This output control is used to set up a new SDM part number in the IPC. |