Removal Procedure
Note: Do not remove any constant tension clamp retaining a bellow to an air cleaner elbow. Once a constant tension clamp is removed the integrity of the clamp is damaged. The sealing joint between a bellow and the air cleaner bellow
should not be broken. Once this joint is broken, the air cleaner duct assembly must be replaced.
- Remove the air cleaner assembly. Refer to 
Air Cleaner Assembly Replacement.
 
- Loosen the air cleaner outlet duct clamp (2) at the air intake pipe. 
 
- Remove the air cleaner outlet duct.
 
Installation Procedure
- Install the air cleaner outlet duct to the air intake pipe.
 
- Ensure that the alignment tab (1) on the outlet duct, aligns with the tab (2) on the air intake pipe.
 
Caution: Refer to Fastener Caution in the Preface section.
- Tighten the air cleaner outlet duct clamp (2) at the air intake pipe. 
 
Tighten
Tighten the clamp to 2.5 N·m (22 lb in).
- Install the air cleaner assembly. Refer to 
Air Cleaner Assembly Replacement.