Removal Procedure
Important: When performing the following procedure,
use only hand tools to remove and install the drain and fill plugs.
- Remove the drain plug (2).
- Remove the fill plug (1).
Installation Procedure
- Install the drain plug (2).
Tighten
Tighten the drain plug to 20 N·m (15 lb ft).
- Fill the transfer case to the bottom of the fill plug hole with the approved
fluid.
- Install the fill plug (1).
Tighten
Tighten the fill plug to 20 N·m
(15 lb ft).