Removal Procedure
- Disconnect the actuator assembly electrical connector.
- Remove the actuator assembly mounting bolts.
- Remove the actuator assembly from the transfer case.
- Remove the actuator assembly insulator gasket.
- If required, remove the harness retainer from the harness.
Installation Procedure
- If required, install the actuator assembly harness retainer to the harness.
Note: Ensure the alignment sleeve is in position.
- Install the new actuator assembly insulator gasket on the actuator assembly.
- Install the actuator assembly motor to the transfer case. Rotate the control actuator lever shaft to align to the encoder motor.
Caution: Refer to Fastener Caution in the Preface section.
- Install the mounting bolts for the actuator assembly.
Tighten
Tighten the actuator assembly mounting bolts to 20 N·m (15 lb ft).
- Connect the actuator assembly electrical connector.